T24 – Sheathed thermocouple, compacted MgO insulation with transition fitting and leads protected by Stainless Steel interlocking armor.
Sample shown: T24-SU-6K-CS-LE12-A-2K
T24- __ __ - __ __ - __ __ - __ __ - A - __1 2 3 4 5 6 7 8 9 10
For dual element change prefix T to D1 – Connector: S – Molded on standard plug
S3 – Molded on 3 prong standard plug
P – Put on Standard connector
J – Standard jack
M – Molded on mini plug
MJ - Mini jack
MP – Put on mini connector
O – Open wire end, no connector option
T - Terminals (Specify Type)
2 – Junction Type: G – Grounded
U – Ungrounded
U2 – Separate ungrounded for dual elements
E – Exposed
S – Semi-shielded
3 – Probe length: In inches
As measured from the tip to the first fixed attachment.
4 – Calibration: E K J T
5 – Sheath diameter: AAA - .032”
AA - .040”
A - .062”
B - .090”
C - .125”
D - .188”
E - .250”
6 –Sheath material: H - Hastelloy X ®
I – Inconel ®
S – 304 SS
S10 – 310 SS
S16 – 316 SS
7 – Transition: LA – Stainless Steel with high temperature epoxy (600 0 F)
LC – Stainless Steel with high temperature ceramic potting
LE – Stainless Steel with epoxy potting (5000F)
P - Molded on plastic rated 5250F
8 – Wire length: Length as measured from transition to connector option
9 - Options: RT – Reduced tip (.125” to .062”)
HPT - Hypodermic point – (Tip sharpened to needle point)
Mounting fitting specify size
R – Stainless Steel wire overbraid on lead wires
A – Stainless Steel interlocking armor
10 –Wire insulation: 24 awg .062” diameter and smaller
20 awg .125” diameter and larger
2F – Fiberglass (305)
2T – Teflon FEP (507)
2K – Kapton (513)
2P – PVC (502)