top (24K)
t25.jpg
T25

T25 - Sheathed thermocouple, compacted MgO insulation with transition fitting to flexible leadwire

Sample shown: T25-MU-3K-CI-LE8-R4F
T25-
__
__
-
__
__
-
__
__
-
__
__
-
__
__

1
2

3
4

5
6

7
8

9
10

For dual element change prefix T to D

1 - Connector:
S โ€“ Molded on standard plug
S3 โ€“ Molded on 3 prong standard plug
P โ€“ Put on Standard connector
J โ€“ Standard jack
M โ€“ Molded on mini plug
MJ - Mini jack
MP โ€“ Put on mini connector
O โ€“ Open wire end, no connector option
T - Terminals (Specify Type)
2 - Junction Type:
G โ€“ Grounded
U โ€“ Ungrounded
U2 โ€“ Separate ungrounded for dual elements
E โ€“ Exposed
S โ€“ Semi-shielded
3 - Probe length:
In inches
As measured from the tip to the first fixed attachment.
4 - Calibration:
E K J T
5 - Sheath Diameter:

AAA - .032โ€
AA - .040โ€
A - .062โ€
B - .090โ€
C - .125โ€
D - .188โ€
E - .250โ€

6 -Sheath Material:
H - Hastelloy Xยฎ
I โ€“ Inconelยฎ
S โ€“ 304 SS
S10 โ€“ 310 SS
S16 โ€“ 316 SS
7 - Transistion:
LA โ€“ Stainless Steel with high temperature epoxy (600 F)
LC โ€“ Stainless Steel with high temperature ceramic potting
LE โ€“ Stainless Steel with epoxy potting (500 F)
P - Molded on plastic rated 525 F
GP โ€“ Grounded โ€“ sheath, transition and overbraid *
* Specify A, C, or E for potting material on GP style transition.
8 - Wire length:
Length as measured from transition to connector option
9 - Options:
RT โ€“ Reduced tip (.125โ€ to .062โ€)
HPT - Hypodermic point โ€“ (Tip sharpened to needle point)
Mounting fitting specify size
R โ€“ Stainless Steel wire overbraid on lead wires
A โ€“ Stainless Steel interlocking armor over leads (change Type to T24)
10 - Wire Insulation:
24 awg .062โ€ diameter and smaller
20 awg .125โ€ diameter and larger
2F โ€“ Fiberglass (305)
2T โ€“ Teflon FEP (507)
2K โ€“ Kapton (513)
2P โ€“ PVC (502)
For stranded wire specify 4F, 4T, 4K etc.
Interested in a T25 ?ย ย ย ย ย ย ย ย  Request a Quote
Copyright©2006 Temprel, All Rights Reserved. Produced by Gaslight Media Sitemap